Errors in laboratory medicine occur in the preanalytical, analytical, and postanalytical phases. The errors are mostly detected in the preanalytical period. However, analytical errors are still an important source of error, despite their frequency is reduced significantly in years thanks to developments in laboratories. In this case, an analytical error was noticed during the verification of a patient's results. The direct bilirubin of a 66-year-old male patient admitted to the emergency department was higher than the total bilirubin. The patient's symptoms were fatigue and dyspnoea. Albumin and haemoglobin (Hb) concentrations of the patient were significantly low. After considering the patient's demographics and laboratory results, the laboratory specialist suspected a paraproteinemia interference. Total protein was performed as a reflective test. The albumin/globulin ratio was reversed. Thereafter, serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE) were performed as another reflective tests, respectively. SPEP and IFE results were in favour of monoclonal gammopathy. The patient was directed to a haematologist, underwent a bone marrow biopsy, and the result was reported as Waldenstrom's macroglobulinemia with plasma cell differentiation expressing IgM-Kappa. The patient went on a chemotherapy protocol, and his condition has been improved in subsequent months. Detection of analytical errors is of great importance, like in our case, and may be used as a tool to identify patients who have not yet been diagnosed. The laboratory specialist must dominate the entire process of each test in the laboratory, be aware of the limitations of tests, and turn these disadvantages into advantages when necessary.
Fecal calprotectin is a biomarker for monitoring inflammatory bowel disease (IBD) activity. Our aim, therefore, was to evaluate two new assays, the point of care test Quantum Blue and the Liaison Calprotectin with respect to the Calprest, commonly used assay, and to determine their performance for IBD diagnosis.
We included 73 prospective patients with IBD. Fecal calprotectin was measured and analysed with the routine Calprest assay and two recently introduced assays, the Quantum Blue and the Liaison Calprotectin. Furthermore, we compared the results by Bland and Altman analysis, and Passing-Bablok regression.
We observed no difference in median calprotectin values obtained by the Calprest (94.6 µg/g, 95%CI 66.5 to 166.1) and Liaison assay (101.0 µg/g, 95%CI 48.1 to 180.1) whereas significantly higher concentrations were obtained with the Quantum Blue assay (240.0 µg/g, 95%CI 119.9 to 353.2). The mean absolute and relative difference between the Calprest and Quantum Blue methods was statistically significant (- 162.3 µg/g and - 143.1%). Mean absolute difference between the Calprest and Liaison calprotectin methods was positive (2.2 µg/g). The agreement between assays revealed that Quantum Blue and Calprest have fair agreement with Kappa coefficient of 0.38 (95%CI 0.26 to 0.51). Liaison Calprotectin and Calprest revealed moderate agreement with a weak Kappa coefficient of 0.47 (95%CI 0.32 to 0.62).
Clinicians should be aware of these differences between the assays and avoid comparison of their respective results.
Clinicians should be aware of these differences between the assays and avoid comparison of their respective results.
The study aimed to investigate the prevalence and titres of anti-SARS-CoV-2 antibodies in children treated at the Children's Hospital Zagreb in the first and the second wave of the COVID-19 pandemic. Statistical significance of difference at two time points was done to determine how restrictive epidemiological measures and exposure of children to COVID-19 infection affect this prevalence in different age groups.
At the first time point (13th to 29th May 2020), 240 samples and in second time point (24th October to 23rd November 2020), 308 serum samples were tested for anti-SARS-CoV-2 antibodies by enzyme-linked immunosorbent assay (ELISA) and electrochemiluminescence immunoassay (ECLIA). Confirmation of results and titre determination was done using virus micro-neutralization test. Subjects were divided according to gender, age and epidemiological history.
Seroprevalence of anti-SARS-CoV-2 antibodies differs significantly in two time points (P = 0.010). In first time point 2.9% of seropositive children wive children had protective titre of anti-SARS-CoV-2 antibodies.
It is unclear what is the best strategy for applying patient-based real-time quality control (PBRTQC) algorithm in the presence of multiple instruments. This simulation study compared the error detection capability of applying PBRTQC algorithms for instruments individually and in combination using serum sodium as an example.
Four sets of random serum sodium measurements were generated with differing means and standard deviations to represent four simulated instruments. Moving median with winsorization was selected as the PBRTQC algorithm. The PBRTQC parameters (block size and control limits) were optimized and applied to the four simulated laboratory data sets individually and in combination.
When the PBRTQC algorithm were individually optimized and applied to the data of the individual simulated instruments, it was able to detect bias several folds faster than when they were combined. JH-X-119-01 IRAK inhibitor Similarly, the individually applied algorithms had perfect error detection rates across different magnitudes of bias, whereas the error detection rates of the algorithm applied on the combined data missed smaller biases. The performance of the individually applied PBRTQC algorithm performed more consistently among the simulated instruments compared to when the data were combined.
While combining data from different instruments can increase the data stream and hence, increase the speed of error detection, it may widen the control limits and compromising the probability of error detection. The presence of multiple instruments in the data stream may dilute the effect of the error when it only affects a selected instrument.
While combining data from different instruments can increase the data stream and hence, increase the speed of error detection, it may widen the control limits and compromising the probability of error detection. The presence of multiple instruments in the data stream may dilute the effect of the error when it only affects a selected instrument.JH-X-119-01 IRAK inhibitor