Postoperative computed tomography (CT) was performed to check screw malposition or construction failure.
Of the 10 C1 pedicle screws on postoperative CT, 20% of screws (grade A) were in the ideal position while 80% of screws (grade B) occupied a safe position. Overall, 100% of screws were safe (grade A or B). There were no iatrogenic neurological deficits, VA injury.
Freehand placement of the C1 pedicle screw through the direct visualization technique of the pedicle and serial dilatation technique is safe and effective without intraoperative fluoroscopy guidance.
Freehand placement of the C1 pedicle screw through the direct visualization technique of the pedicle and serial dilatation technique is safe and effective without intraoperative fluoroscopy guidance.
Percutaneous vertebroplasty (VP) has been used for the safe treatment of osteoporotic compression fracture. However, cement leakage is the most common complication. To reduce the leakage of bone cement, we did the gelfoam embolization during VP. The purpose of this study is to compare the safety and feasibility of different two gelfoam embolization technique during VP.
Total 127 patients (146 level) who had the thoracolumbar osteoporotic compression fracture were enrolled. Group A was treated by gelfoam-only technique and, Group B was treated by gelfoam with venography technique. We compared the incidence of bone cement leakage between two groups using post-operative computed tomography scan and X-ray.
Seventy-four patients (81 levels) were treated with gelfoam-only technique (A), and 53 patients (65 levels) were treated with gelfoam with venography technique (B). There were 22 leakages on group A, and 19 leakages on group B. There was no statistical significant difference between two groups (Chi-square test,
-value =0.958). Incidence of leakage to spinal canal was 11 levels in Group A, 3 levels in group B, and there was statistical significant difference (Fisher's exact test,
-value=0.027).
Complication induced by the bone cement leakage are the most careful point during VP. Gelfoam embolization with venography is very easy and safe method. Gelfoam with venography technique could make lower the incidence of cement leakage to spinal canal.
Complication induced by the bone cement leakage are the most careful point during VP. Gelfoam embolization with venography is very easy and safe method. Gelfoam with venography technique could make lower the incidence of cement leakage to spinal canal.
We investigated the clinical and radiological outcomes of a cement augmented anterior reconstruction and decompression without pedicle screw fixation in patients with osteoporotic thoracolumbar vertebral fracture with myelopathy.
There were 2 male and 6 female patients with thoracolumbar fracture and myelopathy included in the study. The mean follow-up period was more than 1 years. The anterolateral decompression and cement augmented anterior reconstruction with poly(methyl methacrylate) (PMMA) was performed. Demographic data, clinical outcomes, perioperative parameters and radiologic parameter were retrospectively evaluated.
The symptoms due to myelopathy were improved in all patients. The preoperative median visual analog scale score for lower back and leg were 8.5 that improved 4.25 and 3 at last follow up. The preoperative function state showed a median Oswestry Disability Index score 61.5 that improved 33. After surgery, preoperative encroachment of the spinal canal (5.12 mm, 37%) was disappeared. read more ies.
Ventriculoatrial shunt (VAS) remains an alternate option for treatment of hydrocephalus in patients with ventriculoperitoneal shunt (VPS) failure. Unfamiliar anatomy for a neurosurgeon has resulted in the VAS falling out of favor as a treatment option. However, there are unsatisfactory reports on the long-term result of VPS, and VAS has been recently re-evaluated. We are to report the simple way to do the VAS using a peel-away sheath in a hybrid operation room.
A jugular vein path was drawn by ultrasound, a small incision was made above the clavicle, and a shunt catheter was tunneled into it. The jugular vein was punctured beside the tunneled catheter with a Seldinger needle under ultrasound guidance. A flexible guide wire was introduced into the vein and 6-Fr peel-away sheath was advanced into the vein along the wire. Under fluoroscopic guidance, the catheter was cut to position approximately mid-level in the atrium. After the guide wire was removed, the distal shunt catheter was passed down. After confirming proper position of the distal catheter under the fluoroscope, the catheter-guiding sheath was pulled out as a peeling-away manner. We performed this surgical procedures in 5 cases.
All the procedures of the VAS using a peel-away sheath were performed in a hybrid operation room Of 5 patients, 3 patients had the distal catheter failures in the peritoneal cavity and 2 patients had shunt A distal catheter was successfully indwelling in all the cases without any difficulties. After the surgery, neither shunt infection nor thromboembolic event happened.
VAS using fluoroscopy and a peel-away sheath is a good alternative option for hydrocephalus patients with shunt failure related to peritoneal cavity complications.
VAS using fluoroscopy and a peel-away sheath is a good alternative option for hydrocephalus patients with shunt failure related to peritoneal cavity complications.
Burr hole trephination is a common treatment for chronic subdural hematoma, intracranial hematoma, and intraventricular hematoma due to its effective drainage of hematoma, minimal invasiveness and short operation time. However, cosmetic complications such as scalp depression can occur. The aim of this study was to evaluate the usefulness of an allogenic acellular dermal matrix (ADM) to prevent scalp depression at the burr hole site.
A retrospective analysis was performed with 75 cases in 66 patients who were treated with burr hole trephination from January 2018 to December 2019. These cases divided into 2 groups; based on the method used to cover the burr hole site Gelfoam packing only (GPO) and ADM. The degree of the scalp depression was measured from the more recent follow-up brain computed tomography scan.
There was a significant difference in the degree of scalp depression between GPO and ADM groups (
=0.003). No significant correlation between patient's age and the degree of scalp depression (GPO
=0.read more